•  

ARMORED CABLES

JACKETED MCXHHW-2, 50% Ground600 Volt Copper4 Conductor

Description

Four copper conductors, stranded and insulated with heat and moisture resistant crosslinked polyethylene (type XHHW-2), phase identified and cabled with suitable fillers (when necessary) and bare copper ground conductor (3 segmented grounds). Cable core covered with binder tape and aluminum or galvanized steel interlocked armor with overall black PVC jacket. Jacket available in colors.

Application

Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2.

Standards

UL 1569
ICEA S-95-658/NEMA WC-70
Flame Rated: CT Use, IEEE 383 (70,000 BTU), ICEA T-29-520
       (210,000 BTU), IEEE 1202/CSA FT-4, Two-Hour Firewall
Temperature Rated at 90°C Wet/Dry
Sunlight Resistant, Gasoline and Oil Resistant II Jacket
Direct Burial (includes encasement in concrete)
Color Code: Black and Numbered (optional color codes available)
RoHS Compliant

VIEW PRODUCT DATA TABLE

Part Number

 

Size
(AWG or Kcmil)

Strand
(no.)

Insulation

Thickness
(mils)

Grounding

Conductors
(AWG)

Diameter

Over Armor
(in.)

PVC Jacket

Thickness
(mils)

Approx.

Diameter Overall
(in.)

Approx.

Net Weight

Aluminum Armor
(lb./1000')

Approx.

Net Weight

Galvanized Armor
(lb/1000')

Ampacity*
(30°C ambient) 90°C Wet/Dry

AAP8/4G3#14

8

  7

45

(3) #14

0.79

50

0.89

     485

     579

55

AAP6/4G3#12

6

  7

45

(3) #12

0.87

50

0.97

     666

     778

75

AAP4/4G3#10

4

  7

45

(3) #10

0.99

50

1.09

     944

  1,077

95

AAP3/4G3#10

3

  7

45

(3) #10

1.05

50

1.15

  1,105

  1,248

115

AAP2/4G3#8

2

  7

45

(3) #8

1.13

50

1.23

  1,368

  1,515

130

AAP1/4G3#8

1

19

55

(3) #8

1.33

50

1.43

  1,685

  1,933

145

AAP1/04G3#6

1/0

19

55

(3) #6

1.43

50

1.53

  2,108

  2,379

170

AAP2/04G3#6

2/0

19

55

(3) #6

1.51

60

1.63

  2,529

  2,829

195

AAP3/04G3#4

3/0

19

55

(3) #4

1.65

60

1.77

  3,178

  3,500

225

AAP4/04G3#4

4/0

19

55

(3) #4

1.79

60

1.91

  3,882

  4,167

260

AAP250/4G3#4

250

37

65

(3) #4

1.91

60

2.03

  4,434

  4,826

290

AAP300/4G3#3

300

37

65

(3) #3

2.05

60

2.17

  5,245

  5,659

320

AAP350/4G3#2

350

37

65

(3) #2

2.17

60

2.29

  6,073

  6,525

350

AAP400/4G3#2

400

37

65

(3) #2

2.27

75

2.42

  6,838

  7,235

380

AAP500/4G3#1

500

37

65

(3) #1

2.45

75

2.60

  8,392

  8,909

430

AAP600/4G3-1/0

600

61

80

(3) 1/0

2.71

75

2.86

10,087

10,653

475

*Per NEC Table 310.15 (B)(16). Four-conductor ampacity assumes three are hot and one is neutral. NOTE: The data shown is approximate and subject to standard industry tolerances.

 

REQUEST QUOTE