ARMORED CABLES

JACKETED MCXHHW-2600 Volt Copper4 Conductor

Description

Four copper conductors, stranded and insulated with heat and moisture resistant, chemically crosslinked polyethylene (type XHHW-2), phase identified and cabled together with suitable fillers (when necessary) and bare copper ground conductor. Cable core covered with mylar binder tape and aluminum or galvanized steel interlocked armor with overall black PVC jacket. Jacket available in colors.

Application

Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2.

Standards

UL 1569
ICEA S-95-658/NEMA WC-70
Flame Rated: CT Use, IEEE 383 (70,000 BTU), ICEA T-29-520
       (210,000 BTU), IEEE 1202/CSA FT-4, Two-hour Firewall
Temperature Rated at 90°C Wet/Dry
Sunlight Resistant, Gasoline and Oil Resistant II Jacket
Direct Burial (includes encasement in concrete)
Color Code: Black and Numbered (optional color codes available)
RoHS Compliant

VIEW PRODUCT TABLE DATA

Part Number

 

Size
(AWG or Kcmil)

Strand
(no.)

Insulation

Thickness
(mils)

Grounding

Conductor
(AWG)

Diameter

Over Armor
(in.)

Jacket

Thickness
(mils)

Approx.

Diameter Overall
(in.)

Approx.

Net Weight

Aluminum Armor
(lb./1000')

Approx.

Net Weight

Galvanized Armor
(lb./1000')

Ampacity*
(30°C ambient) 90°C Wet/Dry

AAP8/4

8

  7

45

10

0.79

50

0.89

     480

     573

  55

AAP6/4

6

  7

45

  8

0.87

50

0.97

     655

     769

  75

AAP4/4

4

  7

45

  8

0.99

50

1.09

     898

  1,031

  95

AAP3/4

3

  7

45

  6

1.05

50

1.15

  1,080

  1,233

115

AAP2/4

2

  7

45

  6

1.13

50

1.23

  1,295

  1,442

130

AAP1/4

1

19

55

  6

1.33

50

1.43

  1,613

  1,861

145

AAP1/04

1/0

19

55

  6

1.43

50

1.53

  1,944

  2,215

170

AAP2/04

2/0

19

55

  6

1.51

60

1.63

  2,366

  2,666

195

AAP3/04

3/0

19

55

  4

1.65

60

1.77

  2,918

  3,240

225

AAP4/04

4/0

19

55

  4

1.79

60

1.91

  3,542

  3,906

260

AAP250/4

250

37

65

  4

1.91

60

2.03

  4,190

  4,582

290

AAP300/4

300

37

65

  3

2.05

60

2.17

  4,936

  5,351

320

AAP350/4

350

37

65

  3

2.17

60

2.29

  5,643

  6,096

350

AAP400/4

400

37

65

  3

2.27

75

2.42

  6,408

  6,805

380

AAP500/4

500

37

65

  2

2.45

75

2.60

  7,842

  8,359

430

AAP600/4

600

61

80

  2

2.71

75

2.86

  9,343

  9,909

475

*Per NEC Table 310.15 (B)(16). Four-conductor ampacity assumes three are hot and one is neutral. NOTE: The data shown is approximate and subject to standard industry tolerances.

 

 

REQUEST QUOTE