TRAY & POWER CABLES
TRAY CABLERW90/ServiceCPE®600 Volt Copper
Resources

Description
Class B stranded copper conductors, insulated with heat and moisture resistant, chemically crosslinked polyethylene (type XHHW-2 VW-1 or RW90 FT-1), phase identified and cabled together, with overall black CPE jacket. Available with tinned conductors.
Application
Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2
Standards
UL 1277
CSA C22.2 #230/#239 TC/CIC (#14 AWG and larger)
ICEA S-95-658/NEMA WC-70
Exposed Runs Rated (TC-ER)**
IMSA 19-1 (K-1 Colors)
Flame Rated: IEEE 383 (70,000 BTU), T-29-520 (210,000 BTU)
(#14 AWG and larger), IEEE 1202/CSA FT-4 (#14 AWG and larger),
Two-hour Firewall VW-1/FT-1 (conductors)
Temperature Rated at 90°C Wet/Dry
Sunlight and Oil Resistant I Jacket
Direct Burial
Color Code: K-2 Solid Colors (optional color codes available)
RoHS Compliant
|
Part Number
|
Number of Conductors
|
Overall Jacket |
Nominal Diameter |
Approx. Net Weight |
|
Part Number
|
Number of Conductors
|
Overall Jacket |
Nominal Diameter |
Approx. Net Weight |
|||||||||
|
*TCCPE14/2FL |
2 (flat) |
45 |
0.36 X 0.22 |
63 |
TCCPE10/2FL |
2 (flat) |
45 |
0.44 X 0.27 |
113 |
||||||||||
|
*TCCPE14/3 |
3 |
45 |
0.38 |
83 |
TCCPE10/3 |
3 |
45 |
0.47 |
155 |
||||||||||
|
*TCCPE14/4 |
4 |
45 |
0.41 |
103 |
TCCPE10/4 |
4 |
45 |
0.51 |
199 |
||||||||||
|
*TCCPE14/5 |
5 |
45 |
0.45 |
125 |
TCCPE10/5 |
5 |
60 |
0.59 |
259 |
||||||||||
|
*TCCPE14/7 |
7 |
45 |
0.49 |
164 |
TCCPE10/7 |
7 |
60 |
0.64 |
344 |
||||||||||
|
*TCCPE14/9 |
9 |
60 |
0.60 |
223 |
TCCPE10/9 |
9 |
60 |
0.75 |
436 |
||||||||||
|
*TCCPE14/12 |
12 |
60 |
0.69 |
293 |
TCCPE10/12 |
12 |
80 |
0.91 |
608 |
||||||||||
|
*TCCPE14/19 |
19 |
60 |
0.80 |
432 |
TCCPE10/19 |
19 |
80 |
1.05 |
909 |
||||||||||
|
*TCCPE14/25 |
25 |
80 |
0.94 |
586 |
TCCPE10/25 |
25 |
80 |
1.18 |
1,166 |
||||||||||
|
*TCCPE14/37 |
37 |
80 |
1.11 |
829 |
TCCPE10/37 |
37 |
80 |
1.40 |
1,677 |
||||||||||
|
|
|||||||||||||||||||
|
TCCPE12/2FL |
2 (flat) |
45 |
0.39 X 0.24 |
84 |
|
|
|
|
|
||||||||||
|
TCCPE12/3 |
3 |
45 |
0.42 |
112 |
|
|
|
|
|
||||||||||
|
TCCPE12/4 |
4 |
45 |
0.46 |
142 |
|
|
|
|
|
||||||||||
|
TCCPE12/5 |
5 |
45 |
0.50 |
173 |
|
|
|
|
|
||||||||||
|
TCCPE12/7 |
7 |
60 |
0.58 |
246 |
|
|
|
|
|
||||||||||
|
TCCPE12/9 |
9 |
60 |
0.67 |
310 |
|
|
|
|
|
||||||||||
|
TCCPE12/12 |
12 |
60 |
0.77 |
408 |
|
|
|
|
|
||||||||||
|
TCCPE12/19 |
19 |
80 |
0.94 |
645 |
|
|
|
|
|
||||||||||
|
TCCPE12/25 |
25 |
80 |
1.04 |
822 |
|
|
|
|
|
||||||||||
|
TCCPE12/37 |
37 |
80 |
1.24 |
1,174 |
|
|
|
|
|
||||||||||
|
*NOTE: The data shown is approximate and subject to standard industry tolerances. |
|||||||||||||||||||