TRAY & POWER CABLES

TRAY CABLE

RW90/PVC

1,000 Volt Copper

4 Conductor

Description

Four copper conductors, stranded and insulated with heat and moisture resistant, chemically crosslinked polyethylene (type USE-2 or RW90 1kV), phase identified and cabled together with fillers (when necessary) and bare copper ground conductor. Cable core covered with binder tape, and overall black PVC jacket. Jacket available in colors.

Application

Suitable for use in hazardous locations: Class I - Div 2, Class II - Div 2

Standards

UL 1277, CSA C22.2 #230 TC
ICEA S-95-658/NEMA WC-70
Exposed Runs Rated (TC-ER)
IMSA 19-1 (K-1 Colors)
Flame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU)
       (1/0 AWG and larger)
, IEEE 1202/CSA FT-4 (1/0 AWG and larger),
       Two-hour Firewall
Temperature Rated at 90°C Wet/Dry
Sunlight and Oil Resistant II Jacket
Direct Burial Color Code: Method 4
       K-2 Solid Colors (#14 AWG - #10 AWG)
       (optional color codes available)

RoHS Compliant

VIEW PRODUCT DATA TABLE

Part Number

 

Size
(AWG or Kcmil)

Strand
(no.)

Insulation

Thickness
(mils)

Grounding

Conductor
(AWG)

PVC Jacket

Thickness
(mils)

Approx.

Diameter Overall
(in.)

Approx.

Net Weight
(lb./1000')

Ampacity*
(30°C ambient) 90°C Wet/Dry

TCXH14/4G

14

  7

  45

14

  45

0.48

     135

    25†

TCXH12/4G

12

  7

  45

12

  60

0.56

     199

    30†

TCXH10/4G

10

  7

  45

10

  60

0.61

     270

    40†

TCXH8/4G

8

  7

  60

10

  60

0.76

     392

  55

TCXH6/4G

6

  7

  60

  8

  80

0.91

     633

  75

TCXH4/4G

4

  7

  60

  8

  80

1.03

     881

  95

TCXH3/4G

3

  7

  60

  6

  80

1.08

  1,072

115

TCXH2/4G

2

  7

  60

  6

  80

1.16

  1,279

130

TCXH1/4G

1

19

  80

  6

  80

1.33

  1,613

145

TCXH1/04G

1/0

19

  80

  6

  80

1.43

  1,958

170

TCXH2/04G

2/0

19

  80

  6

  80

1.54

  2,369

195

TCXH3/04G

3/0

19

  80

  4

  80

1.65

  2,922

225

TCXH4/04G

4/0

19

  80

  4

110

1.86

  3,667

260

TCXH250/4G

250

37

  95

  4

110

2.00

  4,258

290

TCXH300/4G

300

37

  95

  3

110

2.22

  5,071

320

TCXH350/4G

350

37

  95

  3

110

2.25

  5,722

350

TCXH400/4G

400

37

  95

  3

110

2.44

  6,495

380

TCXH500/4G

500

37

  95

  2

140

2.55

  7,878

430

TCXH600/4G

600

61

110

  2

140

2.86

  9,551

475

*Per NEC Table 310.15 (B)(16). Four-conductor ampacity assumes three are hot and one is neutral. †The overcurrent protection for items marked with an obelisk (†) shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per NEC 310-16 footnote. NOTE: The data shown is approximate and subject to standard industry tolerances.

Related Products

TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/PVC
  • 600/1,000 Volt Copper
  • 3 Conductor
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/PVC
  • 600/1,000 Volt Copper
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/PVC, Shielded
  • 600/1,000 Volt Copper
  • 3 or 4 Conductor
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/PVC, Shielded
  • 600/1,000 Volt Copper
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/ServiceCPE®
  • 600/1,000 Volt Copper
  • 3 Conductor
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/ServiceCPE®
  • 600/1,000 Volt Copper
  • 4 Conductor
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/ServiceCPE®
  • 600/1,000 Volt Copper
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/ServiceCPE®, Shielded
  • 600/1,000 Volt Copper
  • 3 or 4 Conductor
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/ServiceCPE®, Shielded
  • 600/1,000 Volt Copper
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus®
  • 600/1,000 Volt Copper, LSZH Jacket
  • 3 Conductor, Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus®
  • 600/1,000 Volt Copper, LSZH Jacket
  • 4 Conductor, Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus® 50% Ground
  • 600/1,000 Volt Copper, LSZH Jacket
  • 3 Conductor, Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus®
  • 600/1,000 Volt Copper, LSZH Jacket
  • Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus®, Shielded
  • 600/1,000 Volt Copper, LSZH Jacket
  • 3 or 4 Conductor, Factory Mutual Group 1
TRAY & POWER CABLES TRAY CABLE
TRAY & POWER CABLESTRAY CABLE
  • XHHW-2 or RW90/EnviroPlus®, Shielded
  • 600/1,000 Volt Copper, LSZH Jacket
  • Factory Mutual Group 1
 

REQUEST QUOTE