•  

SINGLE CONDUCTORS

SERVICEPRO-X®XHHW-2600/1,000 Volt Copper, VW-1, Tinned, CT RatedNo Pulling Lubricant Required

Description

Single tinned copper conductor, stranded and insulated with moisture, heat, and flame resistant, chemically crosslinked polyethylene. Featuring ServicePRO-X® Insulation–No Pulling Lubricant Required (#6 AWG and larger). Available in colors.

Application

Suitable for general purpose wiring, power distribution, and branch circuit wiring, where a cable having superior flame retardance is required. Suitable for use in 105°C dry systems. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade).

Standards

ASTM Standards: B-3 (soft or annealed), B-8 (concentric lay stranded),
       B-33 (tinned), B-787 (combination strand)
UL 44
ICEA S-95-658/NEMA WC-70
Federal Spec. A-A-59544
Flame Rated: VW-1 (all sizes), CT Use/IEEE1202 (1/0 AWG and larger),
       FT-4 (1/0 AWG and larger)
Temperature Rated at 90°C Wet/Dry, Cold Temperature Rated at -40°C
Sunlight Resistant (#6 AWG and larger), Gasoline and Oil Resistant II
Appliance Wiring Material: Style 3578
RoHS Compliant

View Product Data Table

Part Number

 

Size

(AWG or Kcmil)

Strand

(no.)

Insulation Thickness

(mils)

Nominal Diameter Overall

(in.)

Approx. Net Weight

(lb./1000')

Ampacity*

90°C Wet/Dry

XHVWT14BK

14

  7

30

0.133

    19

    35†

XHVWT12BK

12

  7

30

0.152

    28

    40†

XHVWT10BK

10

  7

30

0.175

    41

    55†

XHVWT8BK

8

  7

45

0.233

    66

  80

XHVWT6BK

6

  7

45

0.271

  102

105

XHVWT4BK

4

  7

45

0.320

  155

140

XHVWT3BK

3

  7

45

0.344

  185

165

XHVWT2BK

2

  7

45

0.374

  238

190

XHVWT1BK

1

19

55

0.426

  301

220

XHVWT1/0BK

1/0

19

55

0.467

  374

260

XHVWT2/0BK

2/0

19

55

0.512

  465

300

XHVWT3/0BK

3/0

19

55

0.560

  579

350

XHVWT4/0BK

4/0

19

55

0.619

  723

405

XHVWT250BK

250

37

65

0.702

  850

455

XHVWT300BK

300

37

65

0.759

  997

500

XHVWT350BK

350

37

65

0.806

1,173

570

XHVWT400BK

400

37

65

0.851

1,314

615

XHVWT500BK

500

37

65

0.926

1,651

700

XHVWT600BK

600

61

80

1.047

1,972

780

XHVWT750BK

750

61

80

1.145

2,444

885

*Per NEC Table 310.15 (B)(17). †The overcurrent protection for items marked with an obelisk  (†) shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per NEC 310-17 footnote. NOTE: The data shown is approximate and subject to standard industry tolerances.

 

REQUEST QUOTE