•  

SERVICEDRIVE®

VFD JACKETED MC (ACWU90)RHW-2/CPE2,000 Volt Copper

Description

Three copper conductors, stranded and insulated with heat and moisture resistant, chemically crosslinked polyethylene (type RHW-2), phase identified and cabled together with suitable fillers and three symmetrical bare copper ground conductors. Cable core shielded with 5-mil copper tape, helically applied with 50% overlap for 100% coverage and double tape thickness throughout the cable. Shielded core covered with galvanized steel interlocked armor with overall black CPE jacket. Available with aluminum armor or PVC or EnviroPlus® (LSZH) jacket. Available with 50% grounds*.

Application

For use in VFD applications.

Suitable for use in hazardous locations: Class I - Div 2,
       Class II - Div 2, Class III - Div 1 and 2

*Patented for use with ServiceDrive® connector and termination kit.

Standards

UL 1569, CSA C22.2 #51
ICEA S-95-658/NEMA WC-70
Flame Rated: IEEE 383 (70,000 BTU), IEEE 1202/CSA FT-4,
       UL 1685, Two-hour Firewall
Temperature Rated at 90°C Wet/Dry, Cold Temperature Rated at -40°C
Sunlight Resistant
Direct Burial
Color Code: Black and Numbered
RoHS Compliant

*U.S. Patent No. 7,309,835

VIEW PRODUCT TABLE DATA

Part Number

 

Size
(AWG or Kcmil)

Strand
(no.)

Insulation Thickness
(mils)

Grounding Conductors
(AWG)

Diameter Over Armor
(in.)

Jacket Thickness
(mils)

Approx. Diameter Overall
(in.)

Approx. Net Weight
(lb./1000')

Ampacity**
(30°C ambient) 90°C Wet/Dry

VFD2KGC14/3

 14†

  7

  60

(3) #14

0.63

50

0.73

     376

  25

VFD2KGC12/3

 12†

  7

  60

(3) #14

0.67

50

0.77

     426

  30

VFD2KGC10/3

 10†

  7

  60

(3) #14

0.73

50

0.83

     496

  40

VFD2KGC8/3

  8†

  7

  80

(3) #14

0.87

50

0.97

     658

  55

VFD2KGC6/3

6

  7

  80

(3) #12

0.95

50

1.05

     836

  75

VFD2KGC4/3

4

  7

  80

(3) #12

1.07

50

1.17

  1,064

  95

VFD2KGC3/3

3

  7

  80

(3) #10

1.11

50

1.21

  1,234

110

VFD2KGC2/3

2

  7

  80

(3) #10

1.23

50

1.33

  1,416

130

VFD2KGC1/3

1

19

  95

(3) #10

1.37

50

1.47

  1,806

150

VFD2KGC1/03

1/0

19

  95

(3) #10

1.47

60

1.57

  2,093

170

VFD2KGC2/03

2/0

19

  95

(3) #10

1.57

60

1.69

  2,470

195

VFD2KGC3/03

3/0

19

  95

(3) #8

1.67

60

1.79

  2,945

225

VFD2KGC4/03

4/0

19

  95

(3) #8

1.81

60

1.93

  3,478

260

VFD2KGC250/3

250

37

110

(3) #8

1.93

60

2.05

  4,088

290

VFD2KGC350/3

350

37

110

(3) #6

2.17

60

2.29

  5,359

350

VFD2KGC500/3

500

37

110

(3) #6

2.41

75

2.56

  7,126

430

VFD2KGC600/3

600

61

125

(3) #6

2.65

75

2.80

  8,372

475

VFD2KGC750/3

750

61

125

(3) #4

2.85

75

3.00

10,144

535

UL Listed Only
**Per NEC Table 310.15 (B)(16).
NOTE: The data shown is approximate and subject to standard industry tolerances.

 

REQUEST QUOTE