Marshall University Engineering Building

Case Study:
UNIVERSITY BUILDING

  •  

 

Wire & Cable in a Modern Academic Building

Copper Line Break

OUR SOLUTION      FOLLOW-UP QUESTION

 

 

Weisberg Applied Engineering Complex at Marshall University

SUBMIT A QUESTION

 

APPLIED ELECTRICAL WIRE AND CABLE

The Arthur Weisberg Family Applied Engineering Complex is the first on Marshall University's campus to be LEED certified, and the seventh building in West Virginia to achieve gold status. The gold level certification is quite an accomplishment given the building's size and the incorporation of lab space.

TIME SAVING INSTALLATION WITH SERVICEPLEX® 

According to Travis Bailey, the Environmental Specialist in the Health and Safety Department at Marshall University, the building is 25% more efficient than the average standards for similar facilities. Some of the aspects contributing to this efficiency are a green vegetative roof, unique storm water piping, a heat recovery system, and the use of regional materials—including all the wire used in the building. The miles of specially engineered wire, including Feeder MC and ServicePlex®, were manufactured just 25 miles away at Service Wire Company.

Service Wire did more than just manufacture the wire used in the building. Their sales and engineering team have been involved since the planning stages with John Harris of Bastian & Harris Architects in Charleston, WV.

The $56 million, 150,000-square-foot facility was finished ahead of schedule, according to Shawn Dixon, President of Dixon Electric, the contracting firm for this huge project. Dixon's estimator calculated a labor savings of 40% by using Feeder MC versus traditional pipe and wire. A similar savings was calculated in using ServicePlex® instead of single conductors. Actual savings in man-hours greatly exceeded these estimates.

"Using the Service Wire products saved us a lot of time on this construction, and we will be using them again," Dixon stated.

BEST CHOICE FOR A UNIVERSITY COMPLEX

ServicePlex® is an ideal choice for new commercial building projects. Contractors nationwide have reported that using our prefab twisted cable has proven and reputable results. Colored conductors, and the cost and time savings offer a competitive advantage when bidding on new projects. 

 

White QuotationsFast service, flexible problem solvers, and good communication. They have it all!

 

White QuotationsThey are the best combination of product and personnel in the industry!

COMMERCIAL BUILDING
CABLE SELECTION

Commerical Line Break

Service Wire's products can be used in an array of commercial high-rise building applications. Our most popular wire and cable product for this application is:

  • Bare Copper
  • ServicePRO-X®
  • ServicePLEX®
  • Tray & Power Cable
  • Feeder MC
  • ServiceDRIVE®

 

COMMERCIAL LINE CARD

 

 

Bare (Solid and Stranded) and Tinned (Solid and Stranded) Copper Wire

BARE COPPER 

Solid or Stranded

AVAILABLE:
#16 AWG - 750 Kcmil
Soft, Medium Hard, or Hard Drawn
Tinned or Non-Tinned

Building Wire and Cable for Heavy Commercial Applications

ServicePRO-X®

No Pulling Lubricant Required
(#6 AWG and Larger)

  • XHHW-2 600V/1kV Copper
  • USE-2 or RHW-2 600V/1kV Copper
  • RHW-2 or RW90 1kV/2kV Copper

AVAILABLE:
#14 AWG - 750 Kcmil
Tinned Conductors
VW-1 Rated
Wide Range of Colors
Silicone-Free

ServicePLEX prefab, twisted single conductor building wire

ServicePLEX®

Prefab Twisted Single Conductors

  • XHHW-2 600V/1kV Copper
  • USE-2 or RHW-2 600V/1kV Copper

AVAILABLE:
#14 AWG - 750 Kcmil
2-7 Conductors
Built-In Grounds
Pre-Installed Pulling Heads
Wide Range of Colors
Silicone-Free

Shielded and Non-Shielded Dual Rated 600V/1kV AAP Tray Cable

TRAY CABLE 

TC-ER Rated

  • XHHW-2 Inner Conductors
    Colored, Numbered, or Striped Conductor

AVAILABLE:
Dual Rated 600V/1kV or 2kV
#14 AWG - 750 Kcmil
2-37 Conductors
Tinned or Non-Tinned
Shielded or Non-Shielded
PVC, ServiceCPE®, or EnviroPLUS® Jacket

Aluminum or Galvanized Steel Interlocked Armor (AIA) Feeder MC (Metal-Clad) Cable

FEEDER MC 

Flexible Interlocked MC (UL 1569)

  • XHHW-2 Inner Conductors
    Colored, Numbered, or Striped Conductors

AVAILABLE:
#8 AWG - 600 Kcmil
2-4 Conductors
120V and 480V Color Codes
50% Ground
PVC, ServiceCPE®, or EnviroPLUS® Jacket

Tray and Armor Variable Frequency Drive Cable - ServiceDRIVE VFD Cable System

ServiceDRIVE®

VFD Cable System

  • VFD Tray/Power Cable
    600V/1kV or 2kV Copper
  • VFD Jacketed Armor
    2kV Copper

AVAILABLE:
#14 AWG - 750 Kcmil
PVC, ServiceCPE®, or EnviroPLUS® Jacket

 

Related CASE STUDIES

Data Center Case Study

COMMERCIAL HIGHRISE


We rose to the occassion when producing more than a quarter million feet of cable for this one-of-a-kind Manhattan highrise. By manufacturing all of our cable in the USA, we could deliver all of the product needed in a timely manner. Read how ServicePro-X was the perfect fit for the newly errected Freedom Tower in New York. 

Data Center Case Study

MISSION CRITICAL DATA CENTER


When it comes to powering data centers, tech giants need reliable cable that can keep pace with their processing speed and efficiency. However, the single or parallel conductors commonly used to distribute power can be cumbersome to set up and install. Read how ServicePlex fit the intricate design and confines of the server floor

Wrigley Field Case Study

BASEBALL FIELD


There are times when you cannot afford to sacrifice quality and stock availability. Wrigley Field, home of the Chiago Cubs, was three days away from the opening game and needed a rush order of cable.  Read how Service Wire manufactured a custom order in less than 24 hours.

 

REQUEST QUOTE