Service Wire Co.  

Culloden, WV
800-624-3572

Pittsburgh, PA
800-778-9473

Houston, TX
800-231-9473

Phoenix, AZ
877-623-9473

Home     About     Products     Comex    Support     Contact

Single Conductors

XHHW-2 and XLP USE-2/RHH RHW-2

Photovoltaic Wire

THW & THW-2

SIS

Weatherproof Line Wire

Cathodic Protection & Transformer Riser Wire
EnviroPlus (Low Smoke Zero Halogen Cable)

Tray & Power Cables

XHHW-2/PVC Tray (shielded and non-shielded)

EnviroPlus (shielded and non- shielded)

SER/SEU Copper Service Entrance

Armor Cables

Jacketed Interlocked Armor

Feeder MC

EnviroPlus Armor (our Low Smoke Zero Halogen cable)

Interlocked Armor

ServiceDrive ASD/VFD Cable System

VFD Armor

VFD Tray

VFD Connectors

VFD Termination Kit

Twisted/Aerial Cables

ServicePlex

Copper Service Drop

Preassembled Aerial

400 Hz Cable

Bare Copper

Bare Solid & Stranded

Plater Wire

Contact Wire

Pump & Irrigation

Submersible Pump Cables

Landscape Lighting Cables

UF Irrigation Cables

Sprinkler Control Cables


Technical Pages


Armor Cables

Interlocked Armor
600V / UL Type MC
Galvanized Steel or Aluminum
Multi-Conductor Copper XHHW-2

Description: Conductors are Class B stranded copper, 30 mils, Type XHHW-2, phase identified, and cabled together with a **bare copper ground conductor. Cable Core covered with binder tape, Aluminum or Galvanized steel interlocked Armor, with an overall flame and sunlight resistant PVC Jacket. Jacket available under armor & in colors.

Standards:
UL 1569
Flame Rated: IEEE-383 (70,000 BTU),
ICEA T-29-520 (210,000 BTU),
IEEE 1202/CSA FT-4
Two-hour Firewall rated
Sunlight Resistant for CT Use; Direct Burial1, Oil Resistant II
Jacket
Color Code K-2 / other color codes available
Temperature Rating: 90° C Wet/Dry
ICEA S-95-658/NEMA WC-70

Features:
Suitable for use in NEC Hazardous locations:
• Class I, Div. 2 • Class II, Div. 2


Interlocked Armor
600 Volt
UL Type MC
Galvanized Steel or Aluminum
Copper XHHW-2

Description: 3 or 4 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled together with suitable fillers** and bare copper ground conductor(s). Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant black PVC jacket. Jacket available under armor and in other
colors.

Standards:
UL 1569
Flame Rated: IEEE-383 (70,000 BTU),
ICEA T-29-520 (210,000 BTU),
IEEE 1202/CSA FT-4
Two-hour Firewall rated, (2/0 AWG and smaller)
Sunlight Resistant for CT Use; Direct Burial1,
Oil Resistant II Jacket
Color Code Black and Numbered / other color codes available
Temperature rating at 90° C Wet/Dry
ICEA S-95-658/NEMA WC-70

Features:
Suitable for use in NEC Hazardous locations:
• Class I, Div. 2 • Class II, Div. 2


Interlocked Armor
600 Volt / UL Type MC
50% Ground
Galvanized Steel or Aluminum
Copper XHHW-2

Description: 3 or 4 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled together with suitable fillers** and bare copper ground conductor (3 segmented grounds). Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant black PVC jacket. Jacket available under armor and in other colors.

Standards:
UL 1569
Flame Rated: IEEE-383 (70,000 BTU),
ICEA T-29-520 (210,000 BTU),
IEEE 1202/CSA FT-4
Two-hour Firewall rated, (2/0 AWG and smaller)
Sunlight Resistant for CT Use; Direct Burial1,
Oil Resistant II Jacket
Color Code Black and Numbered / other color codes available
Temperature rating at 90° C Wet/Dry
ICEA S-95-658/NEMA WC-70

Features:
Suitable for use in NEC Hazardous locations:
• Class I, Div. 2 • Class II, Div. 2


Interlocked Armor
2000 Volt Type MC
Galvanized Steel or Aluminum
Copper RHH or RHW-2

Application: Service Wire’s 2000 Volt Interlocked Armor Cables are designed for use in industrial power distribution systems where continuity of service is the prime consideration. These cables may be installed in wet or dry locations, directly buried or embedded in concrete. Cables are also suitable for use in cable tray.

Description: 3 Conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and bare copper grounding conductor. Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame, oil and sunlight resistant black PVC jacket. Jacket available under armor and in other colors. Available with EnviroPlus® jacket.

Standards:
ICEA S-95-658 / NEMA WC-70
UL 44
UL 854
UL 1569

Features:
Temperature rating 90° C Wet /Dry
Flame Rated: IEEE-383 (70,000 BTU),
ICEA T-29-520 (210,000 BTU),
IEEE 1202/CSA FT-4
Two-hour Firewall rated, (2/0 AWG and smaller)
Sunlight Resistant for CT Use; Direct Burial1,
Oil Resistant II Jacket
Excellent mechanical protection
Suitable for use in NEC Hazardous locations:
Class I, Div. 2; Class II, Div. 2
Factory Mutual Group 1 upon request.


Interlocked Armor
2000 Volt Type MC
Galvanized Steel or Aluminum
Copper RHH or RHW-2

Application: Service Wire’s 2000 Volt Interlocked Armor Cables are designed for use in industrial power distribution systems where continuity of service is the prime consideration. These cables may be installed
in wet or dry locations, directly buried or embedded in concrete. Cables are also suitable for use in cable tray.

Description: 4 Conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and bare copper grounding conductor(s). Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame, oil and sunlight resistant black
PVC jacket. Jacket available under armor and in other colors. Available with EnviroPlus® jacket.

Standards:
ICEA S-95-658 / NEMA WC-70
UL 44
UL 854
UL 1569

Features:
Temperature rating 90° C Wet /Dry
Flame Rated: IEEE-383 (70,000 BTU),
ICEA T-29-520 (210,000 BTU),
IEEE 1202/CSA FT-4
Two-hour Firewall rated, (2/0 AWG and smaller)
Sunlight Resistant for CT Use; Direct Burial1,
Oil Resistant II Jacket
Excellent mechanical protection
Suitable for use in NEC Hazardous locations:
Class I, Div. 2; Class II, Div. 2
Factory Mutual Group 1 upon request.


Interlocked Armor
5kV/2.4kV MV - 105
Nonshielded/Shielded
UL Type MC
Galvanized Steel or Aluminum
5000/2400 Volt Copper EPR

Description:
Nonshielded: Class B stranded copper, extruded conductor shield, insulated with heat and moisture resistant ethylene propylene rubber (2,400 Volt rated).

Shielded: Class B stranded copper, extruded conductor shield, heat and moisture resistant ethylene propylene rubber (100% and 133% insulation level), semi-conducting insulation shield, copper shield, and overall PVC jacket. 3 conductors cabled together with suitable fillers** and bare copper ground conductor. Cable core covered with binder tape, aluminum or galvanized interlocked armor, with flame
and sunlight resistant yellow PVC jacket. Jacket available under armor and in other colors.

Standards:
UL 1072
Flame Rated: IEEE-383 (70,000 BTU),
ICEA T-29-520 (210,000 BTU),
IEEE 1202/CSA FT-4
Class 1 Div II
Sunlight Resistant for CT Use; Direct Burial1,
Two-hour Firewall rated, (2/0 AWG and smaller)
Oil Resistant II Jacket
Color Code K-2/other color codes available
Conductors rated at 105° C
Non-shielded: ICEA S-96-659/NEMA WC-71
Shielded: ICEA S-93-639/NEMA WC-74


Interlocked Armor
15kV MV - 105
133% Insulation Level
UL Type MC
Galvanized Steel or Aluminum
15,000 Volt Copper EPR

Description: 3 conductors, Class B stranded annealed copper, extruded semiconducting shield, heat and moisture resistant ethylene propylene
rubber type EPR, 133% insulation level, semi-conducting insulation shield, copper shield, overall PVC jacket. Cabled together with suitable fillers** and bare copper ground conductor. Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant red PVC jacket. Jacket available under armor and in other colors.

Standards:
UL 1072
Flame Rated: IEEE-383 (70,000 BTU),
ICEA T-29-520 (210,000 BTU),
IEEE 1202/CSA FT-4
Class 1 Div II
Sunlight Resistant for CT Use; Direct Burial1,
Two-hour Firewall rated, (2/0 AWG and smaller)
Oil Resistant II Jacket
Color Code K-2/other color codes available
Conductors rated at 105° C
ICEA S-93-639/NEMA WC-74

 

 

 


Interlocked Armor 600 volt / UL Type MC Multi-Conductor Copper XHHW-2

 

 

 

 

 


 

 


Interlocked Armor 600 volt / UL Type MC Galvanized Steel or Aluminum XHHW-2

 

 

 

 


 

 

 

 


Interlocked Armor 600 Volt / UL Type MC 50% Ground
Galvanized Steel or AluminumCopper XHHW-2

 

 

 

 

 

 

 

 

 


Interlocked Armor 2000 Volt Type MC Galvanized Steel or Aluminum Copper RHH or RHW-2

 

 

 

 

 

 

 

 

 

 

 

 


Interlocked Armor2000 Volt Type MC Galvanized Steel or Aluminum Copper RHH or RHW-2

 

 

 

 

 

 

 

 

 

 

 

 


Interlocked Armor 5kV/2.4kV MV - 105 Nonshielded/Shielded UL Type MC Galvanized Steel or Aluminum 5000/2400 Volt Copper EPR

 

 

 

 

 

 

 

 

 

 


Interlocked Armor 15kV MV - 105 133% Insulation Level
UL Type MC Galvanized Steel or Aluminum 15,000 Volt Copper EPR