ServiceDrive® ASD/VFD Cable System
 

ServiceDrive® ASD/VFD
Shielded Tray Drive Cable
PVC Jacket Overall
Patented

Description: 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors.

Features:
Suitable for use in NEC Hazardous Locations:
Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2
For use in ASD / VFD applications

Standards:
UL 1277
Flame Rated: IEEE 383 (70,000 BTU),
ICEA T-29-520 (210,000 BTU) on 1/0 and larger
IEEE 1202 / CSA FT-4
Two-hour Firewall rated, (2/0 AWG and smaller)
Sunlight Resistant, for CT Use; Direct Burial
Oil Resistant II Jacket
Code: Black and Numbered
Temperature Rating: 90°C Wet / Dry
ICEA S-95-658 / NEMA WC-70
Exposed runs rated #4 and larger
600 Volt Tray Cable
RoHS Compliant


ServiceDrive® ASD/VFD Shielded Tray Drive Cable PVC Jacket Overall Patented

ServiceDrive Plus® ASD/VFD
Shielded Tray Drive Cable
Factory Mutual Group 1 Listed,
Zero Halogen, Limited Smoke,
Lead Free, Patented

Description: 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 symmetrical bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black zero-halogen, limited smoke, zero lead jacket.

Features:
Suitable for use in NEC Hazardous Locations:
Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2
For use in ASD / VFD applications

Standards:
UL 1277
Flame Rated: IEEE 383 (70,000 BTU),
IEEE 1202 / CSA FT-4, UL 1685 LS
Factory Mutual Group 1 Listed
Two-hour Firewall rated, (2/0 AWG and smaller)
Sunlight Resistant, for CT Use; Direct Burial
Color Code: Black and Numbered
Temperature Rating: 90° C Wet / Dry
ICEA S-95-658 / NEMA WC-70
Zero Halogen, Limited Smoke
Exposed Runs 6 AWG and larger
600 Volt Tray Cable
RoHS Compliant


ServiceDrive® ASD/VFD Shielded Tray Drive Cable Factory Mutual Group 1 Listed, Zero Halogen, Limited Smoke, Lead Free, Patented

 
 
Share This 
 
 
 
 
 
 
Service Wire Videos

Service Wire Video Content
 
 
Contact Us:

Service Wire Company Corporate Offices
310 Davis Road
Culloden, WV 25510

800.624.3572 - Culloden, WV
800.231.9473 - Houston, TX
877.623.9473 - Phoenix, AZ