Photovoltaic Wire for use with Solar Panels
600 Volt Single Conductor Power Cable
USE-2 or RHH or RHW-2
Description:Single copper conductor, stranded, insulated with moisture and
heat resistant cross-linked polyethylene. Rated 600V to meet the
challenging requirements of transformeress inverters on
photovoltaic (solar) panel installations.
Temperature rating is 90° C in wet and dry applications.
Applications:
Photovoltaic wire (600 Volt) for use as interconnection wiring on
solar panels in grounded or ungrounded systems as defined in
applicable parts of the National Electrical Code (NEC) NFPA 70,
such as article 690.31(A).
Standards:
ASTM B3 & B8
UL 44, UL 854, UL 4703,
Direct Burial Rated
Flame Rated: VW-1 per UL 1685
Federal Spec. A-A-59544
ICEA S-95-658/NEMA WC-70
CT rated 1/0 and larger
Sunlight Resistant
#14-4/0 Rated L-824C
-40° C rated
Suitable for use in 105 C Dry System
RoHS Compliant
Photovoltaic Wire For use with Solar Panels 600 Volt
Photovoltaic Wire for use with Solar Panels
2000 Volt Single Conductor Power Cable
USE-2 or RHH or RHW-2
Description: Single copper conductor, stranded, insulated with moisture and
heat resistant cross-linked polyethylene. Rated 2KV to meet the
challenging requirements of transformerless inverters on
photovoltaic (solar) panel installations.
Temperature rating is 90° C in wet and dry applications.
Application: Photovoltaic wire (2,000 Volt) for use as interconnection wiring on
solar panels in grounded or ungrounded systems as defined in
applicable parts of the National Electrical Code (NEC) NFPA 70,
such as article 690.31(A).
Standards:
ASTM B3 & B8
UL 44, UL 854, UL 4703,
Direct Burial Rated,
Flame Rated: VW-1 per UL 1685
Federal Spec. A-A-59544
ICEA S-95-658/NEMA WC-70
CT rated 1/0 and larger
Sunlight Resistant
#14-4/0 Rated L-824C
-40° C rated
Suitable for use in 105 C Dry System
RoHS Compliant
Photovoltaic Wire for use with Solar Panels 2000Volt
Photovoltaic Wire for use with Solar Panels
600 Volt Single Conductor Power Cable
USE-2 or RHH or RHW-2
Zero Halogen, Limited Smoke Jacket
Description: Single conductor insulated with heat and moisture resistant,
cross-linked polyethylene insulation, (Type USE-2), with an
overall flame and sunlight resistant, Zero Halogen, Limited
Smoke, Zero Lead Jacket. Tinned conductors available.
Application:
Photovoltaic wire (600 Volt) for use as interconnection wiring on
solar panels in grounded or ungrounded systems as defined in
applicable parts of the National Electrical Code (NEC) NFPA 70,
such as article 690.31(A).
Standards:
UL 4703 (PV Wire)
Conductors UL854 (#16 per UL 66)
ICEA S-95-658/NEMA WC-70
Flame Rated: VW-1 per UL 1685
Direct Burial Rated
Temperature Rating: 90° C Wet and Dry
Sunlight Resistant; Superior Water Resistance
Excellent crush and abrasion resistance
Zero Halogen, Limited Smoke Jacket
RoHS Compliant
Photovoltaic Wire for use with Solar Panels 600 Volt