TWISTED CABLES

PREASSEMBLED AERIALXHHW-2 or RW90600/1,000 Volt Copper

Description

Three or four copper conductors, stranded and insulated with heat and moisture resistant, chemically crosslinked polyethylene (type XHHW- 2 or RW90), cabled together with a left hand lay and messenger of 30% EHS copperweld, laid parallel and bound with a flat bare copper binding strap. Available with galvanized or stainless steel messengers, PVC coated copper, and stainless steel strap.

Reference Materials

Standards

UL 44
ICEA S-95-658/NEMA WC-70
Temperature Rated at 90°C Wet/Dry, Cold Temperature Rated at -40°C
Sunlight Resistant
RoHS Compliant

VIEW PRODUCT DATA TABLE

Part Number

 

Size
(AWG or Kcmil)

Strand
(no.)

Insulation Thickness
(mils)

Messenger Size **
(in.)

Messenger Size **
Strand (no.)

Approx. Diameter Overall
(in.)

Approx. Net Weight
(lb./1000')

Ampacity*
(40°C ambient)

AER1/4C8/3

8

  7

45

1/4

7

0.74

     428

  66

AER1/4C6/3

6

  7

45

1/4

7

0.83

     532

  89

AER1/4C4/3

4

  7

45

1/4

7

0.93

     695

117

AER1/4C2/3

2

  7

45

1/4

7

1.05

     947

158

AER1/4C1/3

1

19

55

1/4

7

1.16

  1,139

185

AER1/4C1/03

1/0

19

55

1/4

7

1.25

  1,369

214

AER5/16C2/03

2/0

19

55

5/16

7

1.41

  1,728

247

AER5/16C3/03

3/0

19

55

5/16

7

1.51

  2,078

287

AER3/8C4/03

4/0

19

55

3/8

7

1.72

  2,643

335

AER3/8C250/3

250

37

65

3/8

7

1.83

  3,017

374

AER1/2C350/3

350

37

65

1/2

7

2.15

  4,199

464

AER9/16C500/3

500

37

65

9/16

7

2.48

  5,804

580

AER9/16C750/3

750

61

80

9/16

7

2.91

  8,291

747

 

AER1/4C8/4

8

  7

45

1/4

7

0.81

     495

  66

AER1/4C6/4

6

  7

45

1/4

7

0.90

     633

  89

AER1/4C4/4

4

  7

45

1/4

7

1.02

     850

117

AER1/4C2/4

2

  7

45

1/4

7

1.15

  1,185

158

AER1/4C1/4

1

19

55

1/4

7

1.27

  1,439

185

AER5/16C1/04

1/0

19

55

5/16

7

1.43

  1,825

214

AER5/16C2/04

2/0

19

55

5/16

7

1.54

  2,197

247

AER3/8C3/04

3/0

19

55

3/8

7

1.74

  2,788

287

AER3/8C4/04

4/0

19

55

3/8

7

1.88

  3,374

335

AER1/2C250/4

250

37

65

1/2

7

2.11

  4,069

374

AER1/2C350/4

350

37

65

1/2

7

2.35

  5,381

464

AER9/16C500/4

500

37

65

9/16

7

2.71

  7,472

580

AER9/16C750/4

750

61

80

9/16

7

3.20

10,785

747

*Per NEC Table 310.15 (B)(20). Four-conductor ampacity assumes three are hot and one is neutral. **Messenger size based on 150’ span with sag of 2.5 ft. NOTE: The data shown is approximate and subject to standard industry tolerances.

 

 